Systems Specifications Internal Mild Steel

 

Surface Preparation: Ensure surfaces are degreased and free of contamination using A925- Metal degreaser

(follow instructions as per data sheet).

Ensure all Corroless data sheet preparation procedures are strictly followed such as spread rates, abrasive blasting, power tool

cleaning and water jet standards etc. Apply 1st coat within 4 hours of abrasive blasting. Practical coverage is project dependent.

Ensure surfaces are free from preparation debris and are clean and dry.

 

Click on links to obtain Corroless data sheets.

 

DFT = Dry Film Thickness    WFT = Wet Film thickness    TDF = Total Dry Film thickness

 

Spec 01

 

Internal/Dry Exposure

Preparation: Corroded steel power wire brushed to a bright surface to St 2 AS 1627.9. Alkyd Single pack system

1st Coat

Apply  Corroless S1 or S2 at 80 µ WFT (35 µ DFT)

                                               

2nd and 3rd coat

Apply  Corroless RF 15 at 120 µ WFT  (60 µ DFT ) tinted to approved colour

 

TDF = 155 microns minimum

 

Spec 02

 

 Internal/Wet Exposure

 

Preparation: Abrasive Blasting Sa 3 of AS 1627.9.

Two pack system

1st coat:

 

Apply Corroless E at 90 µ WFT( 50 µ DFT)           

2nd and 3rd

 Apply Corroless RF 60 at 50 µ WFT ( 30 DFT)

 

 

TDF = 110 microns minimum

 

Spec 03

 

Internal/PH/Chemicals/Humidity

 

Preparation: Abrasive Blasting Sa 3 of AS 1627.9.

Two pack system

1st coat:

 

Apply Corroless EP at 210 µ WFT( 200 µ DFT)     

2nd and 3rd

 Apply Corroless RF 35 at 210 µ WFT ( 200 DFT)

 

 

TDF = 600 microns minimum

 

Specification subject to NZS/AS 1627; Preparation of surfaces NZS/AS 2312 Protection of mild steel; AS 3894 Determination of Dry Film thickness