Systems Specifications Specific Conditions
Surface Preparation: Ensure surfaces are degreased and free of contamination using Protective Paints A925 - Metal degreaser (follow instructions as per data sheet). Ensure all Corroless data sheet preparation procedures are strictly followed. Ensure surfaces are free from preparation debris and are clean and dry.Apply 1st coat within 4 hours of abrasive blasting. Practical coverage is project dependent.
Click onto links to obtain Corroless data sheets.
DFT = Dry Film Thickness WFT = Wet Film thickness TDF = Total Dry Film thickness
Spec 016
|
High Temperatures up to 200°C |
Geothermal Hydrothermal steam pipes and bores Abrasive Blasting Sa 3 of AS 1627.9 (Two pack system) |
|
1st Coat |
Apply
Corroless E at 80 µ WFT (50 µ DFT)
|
|
2nd and 3rd coat |
Apply Corroless RF 60 at 50 µ WFT ( 30 DFT) tinted to approved colour |
TDF = 110 microns minimum
Spec 017
|
Non-Skid Surfaces |
Abrasive
Blasting Sa 3 of AS 1627.9 (Two pack system) |
|
1st coat: |
Apply Corroless EP at 210 µ WFT( 200 µ DFT).Spread 100g/m2 of aluminium oxide into wet coating |
|
2nd and 3rd |
Apply Corroless RF 60 at 50 µ WFT ( 30 DFT) tinted to approved colour |
The RF 60 will encapsulate the grit leaving a suitable non-skid profile.
TDF = 260 microns minimum
Spec 018
|
Int/Immersion
subject to abrasion |
Abrasive Blasting Sa 3 of AS 1627.9 (Two pack system) |
|
1st coat: |
Apply Corroless EP at 210 µ WFT( 200 µ DFT) |
|
2nd and 3rd |
Apply Corroless EP at 210 µ WFT( 200 µ DFT) |
TDF = 600 microns minimum
Specification subject to NZS/AS 1627; Preparation of surfaces NZS/AS
2312 Protection of mild steel; AS 3894 Determination of Dry Film thickness