Systems Specifications Exterior Mild Steel
Surface Preparation: Ensure surfaces are degreased and free of contamination using Protective Paints A925 - Metal degreaser
(follow instructions as per data sheet).Ensure surfaces are free from preparation debris and are clean and dry.
Apply 1st coat within 4 hours of abrasive blasting. Practical coverage is project dependent.
Corroless Data sheets can be obtained from links.
DFT = Dry Film Thickness WFT = Wet Film thickness TDF = Total Dry Film thickness
Spec 04
|
External/ Mild Exposure 5 year durability |
Away from coast and industrial activity Abrasive Blasting Sa 3 of AS 1627.9 (Alkyd System) |
|
1st Coat |
Apply
Corroless S1 or S2 at 80 µ WFT (35 µ DFT)
|
|
2nd and 3rd coat |
Apply Corroless RF 15 at 120 µ WFT (60 µ DFT ) tinted to approved colour |
TDF = 155 microns minimum
Spec 05
|
External/Coastal
Marine Exposure 8-10+ year durability |
Less Than 10 km from coastal areas of industrial activity Abrasive Blasting Sa 3 of AS 1627.9 (Two pack system) |
|
1st coat: |
Apply Corroless EP at 210 µ WFT( 200 µ DFT) |
|
2nd and 3rd |
Apply Corroless RF 60 at 50 µ WFT ( 30 DFT) tinted to approved colour |
TDF = 260 microns minimum
Spec 06
|
External/ Immersion and Abrasion |
Abrasive Blasting Sa 3 of AS 1627.9 (Two pack system) |
|
1st coat: |
Apply Corroless EP at 210 µ WFT( 200 µ DFT) |
|
2nd and 3rd |
Apply Corroless RF 60 at 50 µ WFT ( 30 DFT) tinted to approved colour |
TDF = 260 microns minimum
Specification subject to NZS/AS 1627; Preparation of surfaces NZS/AS
2312 Protection of mild steel; AS 3894 Determination of Dry Film thickness